⚡ انخفاض السعة

Capacitance diminished

The error "Capacitance Diminished" or "CAPACITANCE CHANGE" or "CAPACITANCE LOST" means that the height sensor does not see metal under the nozzle.

❌ Causes by frequency ❌

0) At machine startup, sensor didn't detect metal and went into error;
1) Rusty metal (iron oxide works worse with inductance);
2) Ceramic ring broken;
3) Coaxial cable doesn't transmit information from sensors to signal amplifier;
4) Data cable from amplifier to control board rubbed through;
5) Ceramic ring installed incorrectly, contacts on ring and nozzle assembly don't match;
6) Contact on nozzle assembly sinks in.

❗SOLUTIONS❗
(follow the order until the error is eliminated)

1) Ensure ceramic ring integrity and correct installation;
• IF BROKEN, REPLACE;

2) Ensure that the gold contact in the nozzle assembly does not "sink" inside;
• IF SINKING, NEED NEW NOZZLE ASSEMBLY;

3) ❗Perform full height sensor calibration cycle (button below takes you to video)❗;

4) Replace coaxial cable from nozzle assembly to signal amplifier;

5) Check data cable integrity from amplifier to control board, test wires with multimeter;
• IF FAULTY, REPLACE.