Fiber laser settings for 1 mm mild steel at 1 kW
Updated:
Short answer
A 1 kW fiber laser cuts 1 mm mild steel with nitrogen or air at 11–16 bar and 6–22 m/min. For this combination we have four regimes: the base one from the source maker’s table and three alternatives from other sources.
Mild steel cutting speed and gas pressure at 1 kW
Base regime · Mild steel · 1 mm · 1 kW
1000W(50u), Cutting head focal length: Collimating 100/Focal 125
Gas
N₂ / air
Gas pressure
14bar
Speed
20–22m/min
Power
100%
Frequency
5000Hz
Duty cycle
100%
Focus
in the app
Cutting height
in the app
Nozzle
in the app
Alternative 1 · Mild steel · 1 mm · 1 kW
Raycus 1000W, Head: none
Gas
N₂ / air
Gas pressure
16bar
Speed
10m/min
Power
100%
Frequency
5000Hz
Duty cycle
100%
Focus
in the app
Cutting height
in the app
Nozzle
in the app
Alternative 2 · Mild steel · 1 mm · 1 kW
1000W, Head: ProCutter
Gas
N₂ / air
Gas pressure
16bar
Speed
6m/min
Power
100%
Frequency
1000Hz
Duty cycle
100%
Focus
in the app
Cutting height
in the app
Nozzle
in the app
Alternative 3 · Mild steel · 1 mm · 1 kW
Max MFSC-1000X QBH, Head: none
Gas
N₂ / air
Gas pressure
11bar
Speed
12.5m/min
Power
100%
Frequency
5000Hz
Duty cycle
100%
Focus
in the app
Cutting height
in the app
Nozzle
in the app
Which regime to start with
- Base regime. The starting point for most 1 kW machines, from the source maker’s own table.
- Alternative 1. Slower: 10 m/min against 20–22 m/min. Gas pressure 2 bar higher. Source: Raycus 1000W, Head: none. Try it when the base regime does not cut through or leaves burr on the bottom edge.
- Alternative 2. Slower: 6 m/min against 20–22 m/min. Gas pressure 2 bar higher. Source: 1000W, Head: ProCutter. Try it when the base regime does not cut through or leaves burr on the bottom edge.
- Alternative 3. Slower: 12.5 m/min against 20–22 m/min. Gas pressure 3 bar lower. Source: Max MFSC-1000X QBH, Head: none. Try it when the base regime does not cut through or leaves burr on the bottom edge.
Cutting time and gas consumption per metre
At these speeds one metre of cut takes about 3–10 seconds. Nitrogen or air flow through the nozzle is about 9.6–76.6 m³ per hour, or 27–64 litres per metre of cut, not counting piercing.
Mild steel cutting speed chart: neighbouring thickness and power
| Thickness · power | Gas | Speed, m/min |
|---|---|---|
| 0.8 mm · 1 kW | N₂ / air | 19 |
| 1 mm · 500 W | N₂ / air | 10–12 |
| 1 mm · 1 kW | N₂ / air | 20–22 |
| 1 mm · 1.5 kW | N₂ / air | 20 |
| 1 mm · 2 kW | N₂ / air | 25 |
| 2 mm · 1 kW | N₂ / air | 6–7 |
| 3 mm · 1 kW | O₂ | 2.8–3 |
Common mild steel cutting defects with nitrogen or air



Not sure which one you have? Send a photo of the edge to the app and it names the defect and the fix.
Related questions
- Can a 1 kW fiber laser cut 1 mm mild steel with oxygen?
- Our tables give only nitrogen or air for 1 mm mild steel: on thin sheet it is faster and leaves a clean edge.
- What is the thickest mild steel a 1 kW fiber laser cuts?
- Our tables go up to 14 mm mild steel at 1 kW, at 0.07 m/min with nitrogen or air. The next thickness, 15 mm, starts from 3 kW.
- Why is the speed a range?
- Sheet surface, mild steel grade, gas purity and pressure at the nozzle and the state of the protective window all shift the result. Start at the lower value, make a test cut and raise the speed in 5% steps while the bottom edge stays clean.
- Where are focus, cutting height and nozzle?
- They depend on the cutting head and lens, so a single number is often wrong for your machine. The app shows the full regime and fits it to the machine you add to your profile.