Fiber laser settings for 2 mm mild steel at 3 kW
Updated:
A 3 kW fiber laser cuts 2 mm mild steel with nitrogen or air at 10–16 bar and 16–22.5 m/min or with oxygen at 0.6–1.6 bar and 3.8–4.2 m/min. For this combination we have seven regimes: two base ones from the source makers’ tables and five alternatives from other sources.
Mild steel cutting speed and gas pressure at 3 kW
Which regime to start with
- Base regime · N₂ / air. The starting point for most 3 kW machines, from the source maker’s own table.
- Oxygen or nitrogen. Nitrogen gives a clean, oxide-free edge ready for painting or welding, and is faster on thin sheet; oxygen needs less power and less gas pressure on thicker plate.
- Alternative 1. Faster: 19 m/min against 16–20 m/min. Gas pressure 6 bar higher. Source: MAX 3000W, Head: WSX. Try it when the cut is clean and you want more speed; if the edge gets worse, go back to the base regime.
- Alternative 2. Faster: 22.5 m/min against 16–20 m/min. Gas pressure 6 bar higher. Source: MAX MFSC-3000X-50um, Head: none. Try it when the cut is clean and you want more speed; if the edge gets worse, go back to the base regime.
- Alternative 3. Faster: 20 m/min against 16–20 m/min. Source: Raycus, Head: WSX. Try it when the cut is clean and you want more speed; if the edge gets worse, go back to the base regime.
- Alternative 4. Oxygen pressure 0.8 bar lower. Source: MAX MFSC-3000X-50um, Head: none. Try it when the top edge burns or the kerf is too wide.
- Alternative 5. Oxygen pressure 1 bar lower. Source: Raycus, Head: Raytools bm111. Try it when the top edge burns or the kerf is too wide.
Cutting time and gas consumption per metre
At these speeds one metre of cut takes about 3–16 seconds. Nitrogen or air flow through the nozzle is about 25–60.3 m³ per hour, or 21–53 litres per metre of cut, not counting piercing. Oxygen flow through the nozzle is about 1–1.4 m³ per hour, or 4–6 litres per metre of cut, not counting piercing.
Mild steel cutting speed chart: neighbouring thickness and power
| Thickness · power | Gas | Speed, m/min |
|---|---|---|
| 1 mm · 3 kW | N₂ / air | 28–35 |
| 2 mm · 2 kW | O₂ | 5.2 |
| 2 mm · 3 kW | N₂ / air | 16–20 |
| 2 mm · 3 kW | O₂ | 3.8–4.2 |
| 2 mm · 4 kW | N₂ / air | 12–15 |
| 2 mm · 6 kW | N₂ / air | 20–25 |
| 3 mm · 3 kW | O₂ | 3.2–3.6 |
| 4 mm · 3 kW | O₂ | 3–3.2 |
Common mild steel cutting defects with nitrogen or air and with oxygen




Not sure which one you have? Send a photo of the edge to the app and it names the defect and the fix.
Related questions
- What is the thickest mild steel a 3 kW fiber laser cuts?
- Our tables go up to 26 mm mild steel at 3 kW, at 0.23 m/min with oxygen. The next thickness, 30 mm, starts from 8 kW.
- Why is the speed a range?
- Sheet surface, mild steel grade, oxygen purity and the state of the protective window all shift the result. Start at the lower value, make a test cut and raise the speed in 5% steps while the bottom edge stays clean.
- Where are focus, cutting height and nozzle?
- They depend on the cutting head and lens, so a single number is often wrong for your machine. The app shows the full regime and fits it to the machine you add to your profile.